Abstract
The changes in the duration of atrial electrograms and the appearance of AF during atrial pacing were compared among five atrial pacing sites in dogs to clarify the arrhythmogenicity of atrial pacing at different atrial pacing sites. In seven mongrel dogs (15-20 kg), the right atrial surface was exposed by right thoracotomy. Atrial electrograms were recorded via bipolar electrodes with an interelectrode distance of 1.2 mm at four right atrial sites: (1) the high right atrium (HRA), (2) the mid-right atrium (MRA), (3) the low right atrium (LRA), and (4) the center of the pectinate muscle (PM). The duration of the atrial electrograms at these four recording sites were measured during atrial pacing with fixed cycle lengths of 200, 150, and 120 ms delivered at five atrial sites: (1) the HRA, (2) the inferior vena cava (IVC), (3) the right atrial appendage (RAA), (4) Bachman's bundle (BB), and (5) the atrial septum (AS). In each dog, the atrial pacing with the 120-ms cycle length was performed five times at each pacing site to evaluate the inducibility of AF. When AF was induced, the atrial recording site which first showed a fragmented atrial electrogram was considered the initiation site of the AF. AF was induced during 9 of 35 episodes of atrial pacing at the HRA site, 11 of 35 at the IVC site, 5 of 35 at the RAA site, 3 of 35 at the BB site, and none at the AS site. The initiation site of AF was in the HRA site in 11 of 28 episodes of induced AF, in the MRA site in 9 of 28, and in the LRA site in 8 of 28. At each recording site, the shorter the paced cycle length, the longer the duration of the atrial electrogram regardless of the pacing site. During the atrial pacing with the 200-ms cycle length, the HRA pacing resulted in the shortest duration of the atrial electrogram at each recording site in comparison with the other pacing sites. However, during atrial pacing at the two shorter paced cycle lengths, the duration of the atrial electrogram was shorter during the pacing at the BB or AS sites in comparison with the other three pacing sites, i.e., the HRA, IVC, and RAA sites. These results were the same for all atrial recording sites, but the prolongation of the atrial electrogram was most prominent at the HRA and MRA recording sites, which are most likely initiation sites of the induced AF. In the canine atria, (1) the initiation sites of AF were likely to be the HRA, MRA, or LRA sites in comparison with the PM site; and (2) the atrial pacing at the BB or AS sites was considered less arrhythmogenic for AF than the pacing at the HRA, LRA, or RAA sites.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.