Abstract

Results obtained for the determination of nitrogen in two tantalum alloys and six niobium alloys by modified Kjeldahl and Leco TC-30 nitrogen—oxygen determinator are compared. In the 5–25 ppm range, for tantalum alloys, the relative standard deviation was 3–9% by the Kjeldahl procedure and 9–11% by the instrumental technique. In the range 30–80 ppm, for niobium alloys, the relative standard deviation was 2–8% by the Kjeldahl procedure and 5–7% by the instrumental technique.