Abstract

Measurement of the vestibular aqueduct on CT scans of the temporal bone is important for the detection of large vestibular aqueduct syndrome; typically this is done in the axial plane. We sought to determine the usefulness of reformats performed in the 45 degrees oblique plane for evaluating the vestibular aqueduct. In addition, we provide reference measurements for the vestibular aqueduct in the 45 degrees oblique plane. MATERIALS AD METHODS: We selected 15 subjects referred for reasons other than sensorineural hearing loss, and without radiographic evidence of abnormality of the inner ear. Two neuroradiologists independently evaluated both axial and 45 degrees oblique images for ease in visualizing the vestibular aqueduct. Then, one of the readers (B.O.) performed reference measurements of the diameter at the mouth and midpoint of the aqueduct. Combining the results of both observers, we judged 82% of vestibular aqueducts as well-defined or easily traced on 45 degrees oblique views, whereas we judged only 55% as well-defined or easily traced on axial views. The difference in the degrees of visualization between the 45 degrees oblique and axial reformats was significant for observer 1 (P =.022) and observer 2 (P =.001). Intraobserver agreement about the visibility of the aqueduct was higher on the 45 degrees oblique than the axial views: (kappa = 0.682, SE = 0.171) for 45 degrees oblique reformats; (kappa = 0.480, SE = 0.145) for axial reformats. On the 45 degrees oblique reformats, the mean external aperture dimension of the vestibular aqueduct was measured as 0.616 +/- 0.133 mm, and the postisthmic segment had a mean width of 0.482 +/- 0.099 mm. The 45 degrees oblique plane gives a more reliable depiction of the vestibular aqueduct than the axial plane in CT evaluation of the temporal bone. This technique can be useful in cases of borderline enlargement of the vestibular aqueduct.

Highlights

  • AND PURPOSE: Measurement of the vestibular aqueduct on CT scans of the temporal bone is important for the detection of large vestibular aqueduct syndrome; typically this is done in the axial plane

  • On the 45° oblique reformats, the mean external aperture dimension of the vestibular aqueduct was measured as 0.616 Ϯ 0.133 mm, and the postisthmic segment had a mean width of 0.482 Ϯ 0.099 mm

  • In CT evaluation of children with sensorineural hearing loss, an enlarged vestibular aqueduct is the most commonly detected imaging abnormality.[1,2]. This diagnosis is made when the diameter of the aqueduct is larger than 1.5 mm at the midpoint of the postisthmic segment.[3]. These measurements are currently taken in the axial plane, previous descriptions and evaluations of the aqueduct with use of pluridirectional tomography were performed in modified lateral and Poschl projections.[3,4,5,6]

Read more

Summary

Introduction

AND PURPOSE: Measurement of the vestibular aqueduct on CT scans of the temporal bone is important for the detection of large vestibular aqueduct syndrome; typically this is done in the axial plane. We sought to determine the usefulness of reformats performed in the 45° oblique plane for evaluating the vestibular aqueduct. We provide reference measurements for the vestibular aqueduct in the 45° oblique plane. MATERIALS AD METHODS: We selected 15 subjects referred for reasons other than sensorineural hearing loss, and without radiographic evidence of abnormality of the inner ear. Two neuroradiologists independently evaluated both axial and 45° oblique images for ease in visualizing the vestibular aqueduct. One of the readers (B.O.) performed reference measurements of the diameter at the mouth and midpoint of the aqueduct

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.