Abstract

BackgroundEnsuring an open airway during cardiopulmonary resuscitation is fundamental. The aim of this study was to determine the success rate of blind intubation during simulated cardiopulmonary resuscitation by untrained personnel. MethodsFour devices were compared in a simulated resuscitation scenario: ILMA (Intavent Direct Ltd, Buckinghamshire, United Kingdom), Cobra PLA (Engineered Medical Systems Inc, Indianapolis, IN), Supraglottic Airway Laryngopharyngeal Tube (SALT) (ECOLAB, St. Paul, MN), and Air-Q (Mercury Medical, Clearwater, FL). A group of 210 paramedics intubated a manikin with continuous chest compressions. ResultsThe mean times to intubation were 40.46 ± 4.64, 33.96 ± 6.23, 17.2 ± 4.63, and 49.23 ± 13.19 seconds (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). The success ratios of blind intubation for the devices were 86.7%, 85.7%, 100%, and 71.4% (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). ConclusionThe study showed that the most efficient device with the shortest blind intubation time was the SALT device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.