Abstract

There is still a debate regarding the most appropriate pleural collector model to ensure a short hospital stay and minimum complications. To study aimed to compare the time of air leak, time to drain removal, and length of hospital stay between a standard water-seal drainage system and a pleural collector system with a unidirectional flutter valve and rigid chamber. A randomized prospective clinical trial was conducted at a high-complexity hospital in São Paulo, Brazil. Sixty-three patients who underwent open or video-assisted thoracoscopic lung wedge resection or lobectomy were randomized into two groups, according to the drainage system used: the control group (WS), which used a conventional water-seal pleural collector, and the study group (V), which used a flutter valve device (Sinapi® Model XL1000®). Variables related to the drainage system, time of air leak, time to drain removal, and time spent in hospital were compared between the groups. Most patients (63%) had lung cancer. No differences were observed between the groups in the time of air leak or time spent hospitalized. The time to drain removal was slightly shorter in the V group; however, the difference was not statistically significant. Seven patients presented with surgery-related complications: five and two in the WS and V groups, respectively. Air leak, time to drain removal, and time spent in the hospital were similar between the groups. The system used in the V group resulted in no adverse events and was safe. RBR-85qq6jc (https://ensaiosclinicos.gov.br/rg/RBR-85qq6jc).