Abstract

To investigate the reliability and comparability of retinal measurements obtained with spectral-domain optical coherence tomography (OCT), optical coherence tomography angiography (OCTA), confocal scanning laser ophthalmoscopy (cSLO) colour images, and fundus autofluorescence (FAF) between two multimodal imaging platforms in eyes with macular pathology and normal, healthy volunteers. This cross-sectional, multi-centre, instrument validation study recruited 94 consecutive subjects. All participants underwent a dilated examination and were scanned consecutively on the Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany) and Nidek Mirante (Nidek Co. Ltd., Gamagori, Japan) devices. Agreement between device images were evaluated from measures of the central retinal thickness (CRT), presence of segmentation and fixation imaging artefacts (IA), foveal avascular zone (FAZ) measurements; as well as sensitivity and specificity values from the detection of atrophy on fundus autofluorescence (FAF), drusen, subretinal drusenoid deposits, geographic atrophy, epiretinal membrane, fibrosis and haemorrhage on multicolour imaging, and agreement between devices and groups. Compared with reference clinical examination, sensitivity values for the identification of retinal features using sole device images ranged from 100% for epiretinal membranes to 66.7% for subretinal drusenoid deposits (SSD). Mean absolute difference for CRT between OCT devices was 3.78μm (95% confidence interval [CI]: - 21.39 to 28.95, P = 0.809). Differences in the superficial and deep capillary plexus FAZ area on OCTA between devices were not statistically significant (P = 0.881 and P = 0.595, respectively). IAs were significantly increased in the presence of macular pathology. Comparison of retinal measurements between the OCT devices did not differ significantly. Common ultrastructural biomarkers of multiple macular pathologies were identified with high sensitivities and specificities, with good agreement between graders, indicating that they can be identified with comparable confidence in retinal imaging between the two devices.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.