Abstract
Abstract Objective In this research it was aimed to evaluate stress distribution on the implants supporting a complete overdenture in addition to compare between two different types of low-profile attachments for implant-retained mandibular overdenture with two techniques (with/without using connecting bar). Materials and methods Two 3D finite element models were constructed simulating supported lower complete overdenture with two implants and with two implants and bar. Where, models components were modeled in 3D on commercial general purpose CAD/CAM software. Four runs were carried out, two runs on each model, as linear static analysis. Results Using bar is generally preferred for mucosa and cortical bone, while its effect can be considered as negligible on overdenture. On the other hand, it slightly increases the stresses on spongy bone. Using bar ensures the same level of energy transfer to the spongy bone and increases its maximum Von Mises stresses by about 50%. In addition, increase in maximum Von Mises stress was noticed by about 1% on cortical bone. Conclusion Using bar is not recommended for patients with flat ridge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.