Abstract

The analytical method to determine aflatoxin M1 in milk by HPLC with immunoaffinity column clean-up and fluorescence detection has been validated by using certified reference materials and spiked samples. These validation data have been analysed to obtain the uncertainty estimation following the bottom-up approach as reported by Eurachem. The results obtained with this method have been compared with the expanded uncertainty calculated from data obtained during the years 2002-2007 by participation in Fapas proficiency testing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.