Abstract
ObjectiveTo compare the ability of lung ultrasound and a clinical method in the confirmation of a selective bronchial intubation by left double-lumen tube in elective thoracic surgery. Material and methodsA prospective and blind, observational study was conducted in the setting of a university hospital operating room assigned for thoracic surgery. A single group of 105 consecutive patients from a total of 130 were included. After blind intubation, the position of the tube was confirmed by clinical and ultrasound assessment. Finally, the fiberoptic bronchoscopy confirmation as a reference standard was used to confirm the position of the tube. Under manual ventilation, by sequentially clamping the tracheal and bronchial limbs of the tube, clinical confirmation was made by auscultation, capnography, visualizing the chest wall expansion, and perceiving the lung compliance in the reservoir bag. Ultrasound confirmation was obtained by visualizing lung sliding, diaphragmatic movements, and the appearance of lung pulse sign. ResultsThe sensitivity of the clinical method was 84.5%, with a specificity of 41.1%. The positive and negative likelihood ratio was 1.44 and 0.38, respectively. The sensitivity of the ultrasound method was 98.6%, specificity was 52.9%, with a positive likelihood ratio of 2.10 and a negative likelihood ratio of 0.03. Comparisons between the diagnostic performance of the 2 methods were calculated with McNemar's test. There was a significant difference in sensitivity between the ultrasound method and the clinical method (P=.002). Nevertheless, there was no statistically significant difference in specificity between both methods (P=.34). A P value<.01 was considered statistically significant. ConclusionLung ultrasound was superior to the clinical method in confirming the adequate position of the left double-lumen tube. On the other hand, in confirming the misplacement of the tube, differences between both methods could not be ensured.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Revista Española de Anestesiología y Reanimación (English Edition)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.