Abstract
In this work, the sigma-delta (MA) and the PWM techniques in boost power factor correction (PFC) systems, are compared. To make a comparison under the same power section operating conditions, the problem of evaluating the average switching frequency arises. Electromagnetic emission for both configurations is also investigated. The results show that the MA approach represents an effective solution for obtaining low distortion and that the introduction of a third level allows it to operate in DCM. Theoretical results were confirmed by simulations and experimental results on a laboratory prototype.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.