Abstract

Purpose: To compare the feasibility of -MIBI scintimammography as a tumor localizing agent in breast lesions in comparison with that of mammography and ultrasonography, and to evaluate the efficacy of these three modalities. Materials and Methods: Sixty-four breast lesions were classified as benign or malignant on the basis of sono-graphic and mammographic criteria and were further analyzed by means of -MIBI scintimammography. The classifications thus obtained were compared with the biopsy findings, and in order to compare the three techniques, the sensitivity, specificity, accuracy, and negative and positive predictive values were calculated for each individual modality. Results: Of 64 histologically proven lesions, 33 were malignant and 31 were benign. Sensitivities and specificities for malignancy were 86.2% and 64.5% for mammography, 87.9% and 76.7% for sonography, and 78.8% and 74.2% for -MIBI scintimammography. Conclusion: Mammography and ultrasonogrphy are reliable diagnostic modalities for the detection of breast cancer. -MIBI scintimammography has a higher specificity than mammography and it may help to reduce unnecessary biopsies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.