Abstract

The aim of the present study was to compare immediate (Im) versus delayed (De) placement of laser-treated implants surface with switching platform to confirm the predictability and performance of this type of implant. The implants were placed in pos exodontia and healed sites at the incisor, canine, premolar, and molar regions of the maxilla or the mandible. A protocol was prepared in which patient age, sex, implant length, diameter, and use of bone graft were recorded. The study included 44 GEASS Srl (Udine, Italy) implants with laser surface and morse taper connection, placed in 27 patients (mean age: 56 years; range: 25-80 years).The survival rates were 100% in the Im group and in the De group. The patients were followed for a minimum of 12 months. Implants with laser surface and morse connection presented when placed in fresh sockets showed similar results to implants placed in mature bone after 12 months of follow-up.