Abstract

The present work compares graphene oxides produced by the Marcano's method and the subsequent reduction process using a microwave system with different power and time sets. The thermal profiles of the reduction processes were analyzed, emphasizing the heat capacity from the 600 W test of 3.44 kJ/K. The X-ray diffraction showed a reduction in the interlayer space and the number of layers in all powers. The infrared and UV-Vis spectroscopy results showed a clear decrease in the bands corresponding to the oxygenated group and partial restoration of aromatic bonds. The Raman spectroscopy showed that the 1000 W power set originated a higher defective structure. The observed results allow the conclusion that the 600 W power promotes a little better result between the analyzed power sets.