Abstract

BackgroundThe aim of this study is to evaluate and compare the safety and efficacy of endoscopic mucosal resection with a cap (EMR-c) with those of endoscopic submucosal dissection (ESD) for rectal neuroendocrine tumors (R-NETs) ≤ 15 mm in diameter, and to analyze the risk factors of incomplete resection.MethodsA total of 122 patients who underwent EMR-c or ESD for R-NETs at the Fourth Hospital of Hebei Medical University between February 2007 and December 2020 were invovled in this study. The clinical outcomes of two groups were compared and evaluated.ResultsA total of 122 patients with 128 R-NETs underwent endoscopic resection (EMR-c, 80; ESD, 48). In terms of duration of operation, EMR-c was significantly shorter than ESD (p < 0.001). Univariate analysis and multivariate analysis suggested that tumor diameter ≥ 8 mm was an independent risk factor for incomplete resection in patients with R-NETs in this study.ConclusionsBoth EMR-c and ESD were safe and effective treatments for R-NETs ≤ 15 mm in diameter. In addition, tumor diameter ≥ 8 mm was an independent risk factor for incomplete resection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.