Abstract

To investigate the clinical outcomes after biodegradable-polymer (BP) and durable-polymer (DP) everolimus-eluting stent (EES) implantation in hemodialysis (HD) patients with coronary artery disease. We enrolled 221 consecutive HD patients successfully treated with EES implantation for coronary lesions. Over the following 2years, we assessed the incidence of target lesion revascularization (TLR) and major adverse cardiac event (MACE), defined as the composite endpoint of TLR, all-cause mortality, or myocardial infarction. We performed a propensity-score matching analysis and collected follow-up coronary angiography data. There were 91 patients in the BP-EES group and 130 in the DP-EES group. Male sex and diabetes rates were significantly lower in the BP-EES group than in the DP-EES group. A debulking device was less frequently used in the BP-EES group than in the DP-EES group (7.6% vs. 21.5%, p = 0.006). TLR occurred in 38 patients, while stent thrombosis was observed in 3 patients; 19 patients died. TLR and MACE rates at 2years were comparable between the two groups (19.2% in the BP-EES group vs. 20.4% in the DP-EES group, p = 0.73 and 26.9% vs. 34.2%, p = 0.93, respectively). In the propensity-score-matched cohort, TLR and MACE rates were similar between the two groups (19.2% in the BP-EES group vs. 18.1% in the DP-EES group, p = 0.69, and 26.9% vs. 30.2%, p = 0.66, respectively). Restenosis rates at follow-up angiography were similar between the two groups (p = 0.79). In hemodialysis patients, BP-EES and DP-EES showed similar 2-year clinical outcomes.