Abstract

The accurate placement of stents for treatment of coronary aorto-ostial lesions (AOLs) is technically challenging. The purpose of this study was to evaluate the efficacy and safety of a stent positioning system with a dedicated nitinol device and compare them with those of the conventional approach for stenting of coronary AOLs. In this prospective, multi-center, open-label, randomized study, conducted from November 2015 to April 2019, patients with coronary AOLs that underwent percutaneous coronary intervention (PCI) were randomly allocated (allocation ratio 1:1) using block randomization method to either a stent positioning system group or a conventional technique group. The primary endpoint was the range of stent slippage when positioning. The following secondary endpoints were applied: (I) the extent of swing of the guiding catheters during stent positioning; (II) the rate of accurate stent placement; (III) the procedure time; and (IV) the incidence of major adverse cardiovascular events (MACEs) including cardiac death, myocardial infarction, target lesion revascularization, and stent thrombosis. During the study period, 139 patients with aorto-ostial coronary artery stenosis were included at 5 centers. A total of 69 patients were allocated to the stent positioning system group and 70 patients to the conventional technique group. Angiographic and clinical success were achieved in 100% of the patients included in both groups. The range of stent slippage was significantly shorter in the stent positioning system group than it was in the conventional technique group [0.64 (0.22; 1.35) vs. 1.11 (0.48; 1.72) mm, P=0.01]. The rate of accurate placement of stents was higher in the stent positioning system group than it was in the conventional technique group (74.6% vs. 57.1%, P=0.03). The extent of guiding catheter swing during the stent positioning [0.24 (0.19; 0.53) vs. 0.23 (0.19; 0.53) mm; P=0.95] and the MACEs rates (1.4% vs. 2.9%, P>0.99) were similar between the 2 groups. The procedural time of the stent positioning system was longer than that of the conventional approach [1.00 (0.50; 1.50) vs. 0.80 (0.50; 1.50) min, P=0.09]. The dedicated stent positioning system was is safer and provides more accurate placement of stents for coronary AOLs than the conventional approach, and the associated prolongation of procedure time is insignificant. Chinese Clinical Trial Registry (ChiCTR), Unique identifier: ChiCTR2100053869. URL: https://www.chictr.org.cn/showproj.html?proj=133280.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.