Abstract
The research on infrared radiant characteristics of typical target is important for the detection and recognition of target, infrared simulation calculation and design of electro-optical countermeasures. Thus it is essential to select appropriate test method and optimal calculation method to improve the test accuracy and reliability of infrared radiant intensity. In this paper, three instruments including SR5000 spectroradiometer (CI, MigdalHaEmek, Israel), remote sensing interferometer spectrometer Tensor37 (Bruker, Germany) and Image IR8325 (InfraTec Ltd, Germany) mid-infrared thermal imager were applied to test the infrared radiant (1μm-3μm,3μm-5μm) intensity of decoy samples. Three methods were designed based on two operational principles including direct test and indirect test. The SR5000 spectroradiometer which is able to obtain the value of radian intensity immediately is regard as direct test. The other two instruments which deduce and calculate infrared radiant intensity according to Planck's law and Lambert's cosine law with some preliminary tested parameters such as the response voltage,the distribution of infrared radiant temperature of flaming samples and calibrated data by blackbody, however, are regard as indirect test. Reasons for the diversity of experiment results were provided through analysis on the concrete measurement theory and detailed calculation methods. Moreover, some rules and suggestions were put forward to improve the test accuracy and reliability of infrared radiant intensity when different methods were adopted. It is shown from experiment results that the average mid-infrared radiant intensity obtained from SR5000 was about 903W/Sr in near-infrared band,whereas Tensor 37 and Image IR8325 was about 834W/Sr and 547 W/Sr respectively. It was proved that maximum relative of calculated results from remote sensing interferometer spectrometer Tensor37 and results measured with SR5000 spectroradiometer is below 13%, which meet the general accuracy requirements. Although rigorous reasoning applied, results gained by Image IR8325 mid-infrared thermal imager varied so much from above-mentioned two instruments and the relative error is about 25%~40%. It is analyzed that complexity of the measurement procedure and similarity hypothesis is the main reason for the errors generated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.