Abstract

PurposeThis paper aims to assess the level of occupants’ satisfaction, comparing older and newer on-campus accommodation buildings in Sydney, Australia, aiming to identify their comfort factors deficiencies in terms of design and construction solutions/strategies (e.g. spatial arrangements, materials, thermal comfort).Design/methodology/approachA post occupancy evaluation survey was used to assess the occupant satisfaction with three on-campus accommodation buildings in The University of New South Wales (UNSW) Sydney. One of the selected buildings is an older building opened for occupation in 1996, and the other two are more recent on campus accommodations buildings. The survey included 11 post occupancy evaluation elements identified through literature review which were categorised into three dimensions: technical, functional and behavioural.FindingsThe results show that the satisfaction levels with thermal and acoustic comfort were below standards for both older and newer buildings. In addition, the older building used in this study was rated low in terms of: indoor air quality, lighting, maintenance and management, vertical transportation facility, room layout and furniture quality, building layout and aesthetics and level of privacy. Such factors related to both functional and behavioural dimensions were of greater satisfaction in newer buildings.Practical implicationsFindings suggest the high priority of strategies that address and improve the thermal and acoustic comfort of older and newer on-campus accommodation buildings if the intention is to enhance students’ satisfaction, especially considering the impact that these facilities have on students’ performance. Thermal performance in different seasons and adaptive thermal comfort activities should be considered in the design of new on-campus accommodation buildings and the retrofit of existing old buildings.Originality/valueOn-campus accommodation is an important facility that supports student learning outcomes and helps students adapt in a new learning environment. A post occupancy evaluation study to assess the adequacy of this facility is still lacking because previous studies have generally focussed on class rooms and work spaces in the education sector. This research compares the user satisfaction of older and newer on-campus accommodation buildings in Australia, to highlight deficiencies and areas for improvement in the design of existing and future buildings.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call