Abstract

This study compared the visual outcome, visual quality, and satisfaction following implantation of the Mix-and-Match bifocal IOLs (+ 2.75 D and + 3.25 D add power Tecnis Multifocal Model), EDOF IOL (Tecnis Symfony IOL), and Trifocal IOL (FineVision PodFT, PhysIOL). All outcomes were compared among the three groups. The manifest refraction indicated that the EDOF group had significantly higher myopic spherical equivalent values than did the others. In the terms of visual acuity, there were no significant differences in far or intermediate visual acuity among the three groups. Only in near (33 cm), the EDOF group had significantly worse binocular visual acuity than did the Trifocal group (p = 0.002). Regarding to defocus curve, the Trifocal group had better defocus curves at near distances (− 2.0 to − 3.5 D; p = 0.001 vs. EDOF) than did the other two groups. In contrast sensitivity test, the EDOF group had relatively lower value than did the other two groups. In reading speed, only at 0.3 logMAR (6.5-point font), Mix-and-Match group had a significantly higher reading speed than did the other two groups (p = < 0.001 vs. EDOF, p = 0.007 vs. Trifocal). also Mix-and-Match group showed significantly fewer visual artifacts. There were no differences between the three groups in terms of patient satisfaction.ClinicalTrials.gov number: NCT04019691.

Highlights

  • This study compared the visual outcome, visual quality, and satisfaction following implantation of the Mix-and-Match bifocal intraocular lenses (IOLs) (+ 2.75 D and + 3.25 D add power Tecnis Multifocal Model), extended depth of focus (EDOF) IOL (Tecnis Symfony IOL), and Trifocal IOL (FineVision PodFT, PhysIOL)

  • There were no significant differences in age, sex, spherical diopter, cylinder diopter, or spherical equivalent (SE) between the three groups preoperatively (Table 1)

  • The manifest refraction performed three months postoperatively indicated that the EDOF group had significantly higher myopic SE values than did the Trifocal group (p = 0.004) in the dominant eyes

Read more

Summary

Introduction

This study compared the visual outcome, visual quality, and satisfaction following implantation of the Mix-and-Match bifocal IOLs (+ 2.75 D and + 3.25 D add power Tecnis Multifocal Model), EDOF IOL (Tecnis Symfony IOL), and Trifocal IOL (FineVision PodFT, PhysIOL). In near (33 cm), the EDOF group had significantly worse binocular visual acuity than did the Trifocal group (p = 0.002). Efforts are being made to correct intermediate visual acuity, as well as far and near distance at the same time. The Mix-and-Match method was introduced to increase intermediate visual a­ cuity[3,4]. In this method, bifocal IOLs with different add powers are implanted. The purpose of this study was to compare these three methods for improving intermediate visual acuity for the first time

Objectives
Methods
Results
Conclusion