Abstract

Reverse osmosis (RO) technique plays an important role in the treatment of secondary biochemical effluent. However, the reverse osmosis concentrate (ROC) with high salinity and organic pollutants generated from this process remains a challenge to be tackled. The O3-assisted UV-Fenton advanced oxidation process (AOP) as a pretreatment for the nanofiltration (NF) was used to treat the ROC of industrial wastewater. The optimal removal rates of COD and UV254 were 80.4 and 77.4%, respectively. In the NF process, four types of commercial NF membranes (NF90 (Dow, USA), DK (GE, USA), NT101, and NT103 (NADIR, Germany)) were used to treat the AOP effluent. The effects of operating pressure and feed temperature on ion rejection were investigated. The results show that NF90 and NT103 membranes had better rejections to monovalent ions, while DK and NT101 membranes could effectively separate monovalent and divalent ions and their ion rejections decreased with the increase of feed temperature. With the NF90 membrane, the highest TDS removal rate of 89.65% was obtained at the operating pressure of 1.2MPa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.