Abstract

BackgroundThe Oxford Foot Model (OFM) and Rizzoli Foot Model (RFM) are the two most frequently used multi-segment models to measure foot kinematics. However, a comprehensive comparison of the kinematic output of these models is lacking. Research questionWhat are the differences in kinematic output between OFM and RFM during normal gait and typical pathological gait patterns in healthy adults?. MethodsA combined OFM and RFM marker set was placed on the right foot of ten healthy subjects. A static standing trial and six level walking trials were collected for normal gait and for four voluntarily adopted gait types: equinus, crouch, toe-in and toe-out. Joint angles were calculated for every trial for the hindfoot relative to shank (HF-SH), forefoot relative to hindfoot (FF-HF) and hallux relative to forefoot (HX-FF). Average static joint angles of both models were compared between models. After subtracting these offsets, the remaining dynamic angles were compared using statistical parametric mapping repeated measures ANOVAs and t-tests. Furthermore, range of motion was compared between models for every angle. ResultsFor the static posture, RFM compared to OFM measured more plantar flexion (Δ = 6°) and internal rotation (Δ = 7°) for HF-SH, more plantar flexion (Δ = 34°) and inversion (Δ = 13°) for FF-HF and more dorsal flexion (Δ = 37°) and abduction (Δ = 12°) for HX-FF. During normal walking, kinematic differences were found in various parts of the gait cycle. Moreover, range of motion was larger in the HF-SH for OFM and in FF-HF and HX-FF for RFM. The differences between models were not the same for all gait types. Equinus and toe-out gait demonstrated most pronounced differences. SignificanceDifferences are present in kinematic output between OFM and RFM, which also depend on gait type. Therefore, kinematic output of foot and ankle studies should be interpreted with careful consideration of the multi-segment foot model used.

Highlights

  • Measuring foot kinematics during gait is of particular interest in patients where static and/or dynamic foot deformities are present

  • Kinematic output of foot and ankle studies should be interpreted with careful consideration of the multi-segment foot model used

  • For Rizzoli Foot Model (RFM) compared to Oxford Foot Model (OFM), hindfoot relative to shank (HFSH) was on average in more plantar flexion (Δ = 6◦) and internal rotation (Δ = 7◦)

Read more

Summary

Introduction

Measuring foot kinematics during gait is of particular interest in patients where static and/or dynamic foot deformities are present. Among the proposed multi-segment foot models, the Oxford Foot Model (OFM) [5] and the Rizzoli Foot Model (RFM) [6, 7] have been used most frequently both clinically and in research [1,3]. The Oxford Foot Model (OFM) and Rizzoli Foot Model (RFM) are the two most frequently used multi-segment models to measure foot kinematics. Significance: Differences are present in kinematic output between OFM and RFM, which depend on gait type. Kinematic output of foot and ankle studies should be interpreted with careful consideration of the multi-segment foot model used

Objectives
Methods
Results
Conclusion