Abstract
In this work, a comparison study was implemented on the pool boiling heat transfer coefficient (BHTC) between the copper sulfate and isopropanol solutions. To precise investigate; the bubble dynamic including departure diameter, departure frequency and active nucleation sites were examined. In addition, ultrasonic waves’ irradiation (25 kHz) was employed to intensive the solutions and improve the dynamic parameters due to cavitation phenomenon. First, although the cooper sulfate had a bigger bubble departure diameter and more active nucleation sites than isopropanole, its heat transef coefficient was lower due to great bubble departure frequency of isopropanol. Finally, Calus model with an average error of 12.8% for isopropanol and Palen with 13.1% for copper sulfate had the lowest errors. Moreover, the isoropanole at 20 V.% with 15% power of ultrasonic irradiation and the cooper sulfate at 10.5 V.% with 35% had the maximum increase in the BHTC as 10.549% and 18.238%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.