Abstract

This research was carried out with the objective of comparison between GenEndo, Protaper Gold, Hero Gold and EdgeFile X3 regarding the effect of different concentrations of NaOCl. About 720 study specimens were included in the study. They were divided into four groups. Each group consisted of 180 files. Group A: GenEndo, Group B: Protaper Gold, Group C: Hero Gold, Group D: EdgeFile X3. Each group of instruments were further subdivided into nine subgroups (n = 20 for each subgroup). Testing of the cyclic fatigue was carried out in artificial canals which were prepared inside the blocks of stainless steel. The stainless steel blocks with artificial canals were established in a receiver that was packed with experimental solutions like distilled water, 5.25% NaOCl and 2.5% NaOCl. The adjustment of temperature was done at 25, 37, and 60°C. The rotation of the instrument was carried out inside the artificial canal as per the instructions of the manufacturer. The instrument was rotated until it got fractured. The time taken by the instrument to fracture was recorded in seconds. The number of cycles to fracture (NCF) was analyzed with the help of the equation (NCF = time to fracture × rpm/60). Surfaces at the site of fracture were examined with the help of a scanning electron microscope (EVOLS10, ZEISS) at magnification (300x and 2000x). It was noticed that there was a statistically significant increase in cyclic fatigue when sodium chloride was used as an endodontic irrigant instead of distilled water. The increase in cyclic fatigue was also observed when 5.25% sodium chloride was used instead of 2.5% sodium hypochlorite. Cyclic fatigue increased on change in temperature from 25 to 37°C and from 37 to 60°C. The difference was statistically significant (p < 0.05). It was observed that resistance against cyclic fatigue on treatment with different irrigation solutions at different temperatures was in the order of GenEndo > Protaper Gold > Hero Gold > EdgeFile X3. The resistance against cyclic fatigue in new NiTi rotary files can be affected significantly by different concentrations of sodium hypochlorite irrigant solution and the GenEndo rotary endodontic instrument has the maximum resistance against cyclic fatigue. Irrigation of the root canal with irrigants, such as sodium hypochlorite (NaOCl) has been recommended strongly. NaOCl is used in the range of 0.5 and 6.5% concentration owing to its antimicrobial activity and tissue dissolution activities, particularly at higher temperatures. It has been postulated that fatigue of rotary endodontic instruments can be influenced by adjoining medium and their concentration.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.