Crossflow filtration with pore blocking is an unsteady system affected by operating conditions. We model pore blocking and solve the governing partial differential equations using the method of lines. The loss in permeability is neither spatially nor temporally uniform. Operating at constant flux results in a greater permeate of clean water but at a higher operating cost than operating at constant pressure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.