Abstract
Four different accelerated corrosion tests on steel are simulated with a Dynamic Electrolyte Film Corrosion model. Based on the time dependent temperature and humidity, combined with the presence of hygroscopic salts, a time dependent electrolyte thickness is calculated. At every timestep, the modeled film thickness dictates the corrosion current. Focussing on the thickness predictions, an elementary corrosion model is adopted to enable the corrosion depth estimations. The trends of the simulated corrosion depths are compared with experimental data obtained with an electrical resistance corrosion sensing system, demonstrating the importance of the electrolyte thickness and composition for a thorough understanding and modeling of atmospheric corrosion on steel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.