Abstract

The purpose of this study was to compare the accuracy and predictive validity of pH, bilirubin, and CO2 in identifying gastric tube placement errors in children. After the tube was inserted into 276 children, the CO2 monitor reading was obtained. Fluid was then aspirated to test pH and bilirubin. Lack of ability to obtain tube aspirate was the best predictor of NG/OG placement errors with a sensitivity of 34.9% and a positive predictive value of 66.7%. Measuring pH, bilirubin, and CO2 of tube aspirate was less helpful. Healthcare providers should suspect NG/OG tube misplacement when no fluid is aspirated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.