Abstract

Background: Accurate temperature measurement is a critical step in evaluating health or disease especially in children and immmunocompromised subjects; inaccurate measurement may lead to improper diagnosis, wrong treatment or inappropriate intervention. Several methods of temperature measurements exist and comparing these gives room for choosing a near ideal method in terms of speed, safety and accuracy. The study aimed to compare the forehead non touch infra-red thermometer with the axilllary mercury-in-glass method of temperature measurement in the Paediatric age-group. Methods: Study was given ethical approval as part of a larger study. Four hundred and thirty seven children aged 1 to 24 months were studied at the well-baby/immunizationclinic of the University of Ilorin Teaching Hospital over a 6-months period. Both non-touch infrared and theregular mercury-in-glass thermometers were used to take the body temperatures. Data were analysed with SPSS version 21. Pearson correlation was used to determine the relationship between the two methods of temperature measurements, while Bland-Altman method was used to test for level of agreement between them. Results: The mean age and SD was 5.81 ± 4.04 months. Pearson correlation showed a positive correlation between the axillary mercury-in-glass and forehead non-touch infra-red thermometry readings (r = 0.281, p ). Also, Bland-Altman method revealed a good agreement between both methods of thermometry as 96% of the readings were within the limits of agreement. Mean difference was 0.09°C (95% confidence interval 0.05 - 0.13). Conclusion: Axillary mercury-in-glass thermometer and forehead non touch infra-red thermometers have a good agreement and can be used interchangeably.

Highlights

  • Evaluation of body temperature is one of the oldest and most important step in the diagnosis of disease [1]

  • Pearson correlation was used to determine the relationship between the two methods of temperature measurements, while Bland-Altman method was used to test for level of agreement between them

  • Pearson correlation showed a positive correlation between the axillary mercury-in-glass and forehead non-touch infra-red thermometry readings (r = 0.281, p < 0.001)

Read more

Summary

Introduction

Evaluation of body temperature is one of the oldest and most important step in the diagnosis of disease [1]. Other sites for taking core temperature are the bladder, tympanic membrane, oesophagus, nasopharynx and trachea [1] These methods are invasive and not routinely feasible. Accurate temperature measurement is a critical step in evaluating health or disease especially in children and immmunocompromised subjects; inaccurate measurement may lead to improper diagnosis, wrong treatment or inappropriate intervention. The study aimed to compare the forehead non touch infra-red thermometer with the axilllary mercury-in-glass method of temperature measurement in the Paediatric age-group. Four hundred and thirty seven children aged 1 to 24 months were studied at the well-baby/immunizationclinic of the University of Ilorin Teaching Hospital over a 6-months period Both non-touch infrared and theregular mercury-in-glass thermometers were used to take the body temperatures.

Objectives
Methods
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.