Abstract

A sequencing batch conventional membrane bioreactor (SB-CMBR) and sequencing batch hybrid membrane bioreactor (SB-HMBR) were operated in parallel under two different hydraulic retention times (HRTs) (namely 12h and 6h), and their chemical oxygen demand (COD) and nutrient removal performance, membrane fouling behavior, and microbial community characteristics were compared. Both systems exhibited high organic matter (> 95%) and ammonium (> 98%) removal performance regardless of the HRT applied. As the HRT was reduced from 12 to 6h, total nitrogen removal slightly increased in both reactors, being higher in the carrier-based MBR, where anoxic zones may have been established within the biofilm. Conversely, total phosphorus removal improved only in the SB-CMBR at the shorter HRT. Moreover, activity batch assays have shown a faster P uptake rate in the SB-CMBR than in the SB-HMBR, a result likely associated with the lower relative abundance of phosphate-accumulating organisms in both adhered and suspended biomass fractions in the hybrid MBR. The results also revealed that more pronounced increases in the transmembrane pressure and, consequently, in the membrane fouling rate at higher COD loading rates were observed in the SB-CMBR, where the soluble microbial products (proteins, polysaccharides, and especially, transparent exopolymer particles), supernatant turbidity, and filamentous bacteria were more significant. Overall, as compared to the conventional MBR, the plastic media-based SB-HMBR showed a lower fouling propensity at all hydraulic conditions tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call