Abstract
We measured the magnetic hysteresis loops (M-H loop) of SmBCO coated conductor (CC) and YBCO-CC by using SQUID-magnetometer. These samples were fabricated by RABiTS method and IBAD method. We found the peak shifts of their M-B loops were qualitatively different. To understand this, we measured the magnetic field profiles, H(x), of SmBCO-CC and YBCO-CC by using scanning Hall probe method and calculated their current profiles, J(x). We found that the contrasting difference of M-B loops of the two types of CC was partly due to the inhomogeneous distributions of field and current, which depend on the sample shapes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.