Abstract
Purpose Columns are structural elements that are predominantly subjected to compressive forces and moments that are to be transferred from the super-structure to the sub-structure. The geometrical shape of a column is a significant factor to be considered. The paper aims to discuss this issue. Design/methodology/approach Pushover analysis is carried out, to study the behavior of RC frames with rectangular and specially shaped columns for the same building layout. Findings Reduction of 27.3 percent in base shear, 67.4 percent in spectral displacement, 66.5 percent reduction in storey displacement, 70.22 percent in storey drift and 0.315 percent reduction in storey shear is observed. Practical implications Special shaped RC columns can effectively enhance the structural behavior of high rise structures under seismic excitation in comparison to those with regular shaped RC columns. Originality/value Applications of special shaped columns in structures have showed a great deal of reduction in displacement and shear forces developed due to seismic activity, for the same area of concrete and steel as in rectangular columns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.