Abstract

Employing a novel microwave plasma-assisted combustion (PAC) facility, we conducted a comparative study on PAC of premixed and nonpremixed methane/air mixtures. Results showed that three different reaction zones (plasma zone, hybrid plasma-flame zone, and flame zone) exist, regardless of the fuel injection patterns of the premixed or nonpremixed. Different fuel injection patterns had different optical emission spectra for the hybrid zones and flame zones, with a major difference being the presence or absence of emissions from CH and C2. A U-shaped ignition curve of plasma power versus fuel equivalence ratio was observed in the premixed PAC, whereas an approximately linear increasing line was in the nonpremixed PAC. Pulsed cavity ringdown spectroscopy was also utilized to measure absolute number densities of the ground state OH(X) radicals in the flame zones for both fuel patterns. Results showed different number density profiles along the flame propagation direction between the premixed and nonpremixed PAC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.