Abstract

Gas pressurized closing switches are one of the most important elements in FLTD-based systems. Improving the trigger performance of gas switches is useful for optimizing the output parameters and the reliability of the FLTD. In this paper, the breakdown characteristics of the trigger gap and the overvoltage gap are studied experimentally. The reasons for the different breakdown performance of the two gaps are also investigated. The results show that the breakdown delay of the trigger gap is more influenced by the trigger voltage, while the breakdown delay of the overvoltage gap is more influenced by the working coefficient and always higher than that of the trigger gap. The jitter of the trigger gap is more influenced by the trigger voltage and accounts more than 60% of the total switch jitter, while the jitter of the overvoltage gap is hardly changed with the trigger voltage as well as the working coefficient and maintains less than 1.4 ns. It is proved that the discharging product from the trigger gap can effectively reduce the breakdown delay and jitter of the overvoltage gap. Based on that, the effect and improvement of pre-ionization on the two gaps are also studied. It is concluded that the jitter of the trigger gap reduces obviously when the pre-ionization is added, while the pre-ionization almost has no effect on the jitter of the overvoltage gap. The jitter of the overvoltage gap is about two times higher than the trigger gap in the pre-ionizing switch.