Abstract

The filtration experiments of two PVDF blending membranes were performed. The critical fluxes of PVDF/PMMA and PVDF/TPU blend membranes were measured by the flux-step method. Then tubular membrane module PVDF/PMMA and PVDF/TPU were used to treat alcohol wastewater. The anti-fouling properties of PVDF/TPU membrane module were better than those of PVDF/PMMA membrane module. The critical fluxes of PVDF/PMMA and PVDF/TPU membrane modules were 24 L/(m2∙h) and 22 L/(m2∙h), respectively. In the alcohol wastewater treatment, TMP and SJ of the tested membranes remained stable during this period and membrane module B was more stable than membrane module A. The CODCr removal rates of two membrane modules reached 48% and 58%, respectively. And the UV254removal rates were 18% and 19%, respectively. Both the turbidity removal efficiency were more than 97% and the average effluent values were below 0.10NTU.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.