Abstract

Membrane fouling, primarily resulting from natural organic matter (NOM) widely existing in water sources, has always been a chief hindrance for the prevalent application of ultrafiltration (UF). Thus, vacuum ultraviolet (VUV)/chlorine process was proposed as a strategy for UF membrane fouling control and ultraviolet (UV)/chlorine process was used for comparison. VUV/chlorine process exhibited more excellent performance on NOM removal than UV/chlorine process. [HO•]ss and [Cl•]ss were calculated as 1.26 × 10−13 and 3.06 × 10−14 M, respectively, and ClO• might not exist under the conditions of 0.08 mM chlorine and 30 min VUV irradiation. [HO•]ss, [Cl•]ss and [ClO•]ss were not available and the formation of reactive radicals was unsustainable in UV/chlorine system. Moreover, VUV/chlorine pretreatment also showed better performance on the reversible and irreversible membrane fouling control than UV/chlorine pretreatment. The dominated fouling mechanism in the final stage of filtration was cake filtration. Additionally, the amount of detected disinfection by-products (DBPs) in VUV/chlorine system was significantly lower than that in UV/chlorine system. During subsequent chlorination disinfection, the yield of DBPs with VUV/chorine pretreatment was higher than that with UV/chlorine pretreatment. VUV/chlorine pretreatment could effectively control DBPs formation when the pretreatment time was extended to 120 min. In summary, VUV/chlorine system presented a most excellent performance on membrane fouling control, NOM degradation and DBPs control.