Abstract

AbstractCarbon fiber strands offer a viable alternative to corrosion-prone steel strands in posttensioning applications. This study focused on a side-by-side comparison of two types of carbon fiber strands with different elastic moduli against steel strands in a 5½∶1 scaled model of a typical interior hammerhead pier of the San Antonio Downtown Y project with two identical cantilever overhangs. Two different strand arrangements were used for posttensioning, with eight and six strands, respectively representing an overdesign and a slight underdesign relative to the factored demand. The model was tested under service and factored flexure and shear loads. The study confirmed the feasibility of using carbon fiber strands in unbonded posttensioning of pier caps. Given the strength-based design of the pier cap, the elastic moduli of different carbon fiber strands did not seem to have affected the serviceability performance with respect to either cracking or deflection. Considering both serviceability and overlo...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.