Abstract

New film dosimeters PVA/(DCP/CR) and PVA/(DCP/BPR) have been prepared through the casting method. The colorimetric properties of both films changed from violet to pink and from green to yellow with exposures to gamma rays between 0–80 and 0–40 kGy, respectively. The color response was accelerated with chloral hydrate to half of the radiation dose between 0–40 and 0–20 kGy for both systems, respectively. The UV–visible spectrophotometer shows outstanding stability of the prepared dosimetric systems. Relative humidity was studied and the response indicated that both films possess very good stability during irradiation.Graphical abstract

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.