Abstract

Data on long-term performance and degradation of field-aged solar photovoltaic modules is widely recognized as necessary for continued technological improvement and market confidence. It is also important that such research should cover various geographical regions of the globe. This paper presents a study on twenty-nine (29) crystalline silicon modules deployed in grid-connected, battery-charging and water-pumping applications. The modules, installed at six different locations in Ghana were aged between 6 and 32 years. Peak power (Pmax) losses ranged from 0.8%/year – 6.5%/year. The Pmax losses were dominated by losses in fill factor (FF) and short-circuit current (Isc). Visually observable defects are also reported.