Abstract Overhead water tank is a water storage facility supported by a tower and constructed at an elevation to provide useful storage and pressure for a water distribution system. Safety as well as working of such structures is considered as very crucial during earthquakes, since they put up for necessities like drinking water, firefighting during fire accidents, etc. Such structures should stay in operating condition even after several earthquakes. This RC overhead water tanks involves huge water mass supported on the top of tank supporting system known as staging. This investigation is basically to discover the seismic behavior of RC overhead water tanks. In this study, a FEM based model is used for finding out the nonlinear seismic performance of RC overhead water tanks with several staging variations. The staging that is different bracing patterns considered in this study in lateral and vertical direction, which relatively increases the strength and stiffness of tank in supporting system. Staad models are prepared and analyze for different seismic zones as well as for cyclonic regions and observed the parameters such as base shear, base moment and lateral displacement. The commercial software STAAD.Pro is used for structural analysis. Since the seismic response of water tank structure depends on its dynamic properties and frequency of ground motion. This seismic analysis of overhead water tank structure cannot be carried out on the basis of maximum value of ground acceleration because of nonavailability of ground acceleration data at every location. Hence for seismic analysis of overhead water tank, earthquake response spectrum analysis is widely used. While using this method, smooth design spectra is used to determine the value of displacement and forces in members at every mode of vibration. Octagonal, Radial, Cross, Alternate tie , Diagonal and X- type bracings are used to analyze the structure under all the seismic zones viz. II, III, IV & V. Also observed the behavior of tank for cyclonic region where wind load is increased by 30%. Analysed the overhead water tanks of same capacity for different bottom dome deviation angles and concluded.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal for Research in Applied Science and Engineering Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.