Abstract
This paper aims to compare the performance of two control schemes viz. hard switched and phase shifted control scheme for full bridge DC-DC converter used in photovoltaic application .The proposed converters are designed for 650W photovoltaic input power. Voltage and current waveforms at various test points like across IGBT, transformer primary and secondary, output etc. are compared and results are presented. From results it can be seen that in phase shift control simultaneous transition of voltage across IGBT and current through IGBT is avoided hence reduction in switching losses , dv/dt, di/dt effects and EMI effects can be achieved. At higher switching frequencies phase shift control scheme is meritorious over hard switched control scheme.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.