Abstract
The processes were modelled using the Aspen Hysys version 11. The paper compared two refrigeration systems with different refrigerants, CO2-N2 and N2-N2, and their expenders. The parameters compared are the liquefaction power, specific power, production capacity, and heat duty of the expander cycle. The liquefaction power of CO2-N2 (547.669kW) is lower than that of N2-N2 (815.85kW). The specific power consumption for CO2-N2 was 0.44096kW/kg, and for N2-N2 was 0.6569kW/kg. The production capacity N2-N2 gave a higher value of 6945.6MTPA than CO2-N2 4904.38MTPA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Global Journal of Engineering and Technology Advances
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.