IntroductionThere is no “gold standard” for the type of plate to be used for distal extra-articular humeral fractures; the most used is plating of each column. The objective was to evaluate the short-term clinical and radiological results of a Y- anatomical and innovative locking plate (YALP). HypothesisThe hypothesis is: this anatomical and innovative locking plate will produce satisfactory and reliable results on extra-articular distal humerus fracture superior to double plate fixation. Materials and methodsIn a retrospective observational multicenter study, all patients with a distal humerus fracture type 13 A2.2 according to AO classification fixed with a new Y-plate (YALP) were compared to the results of double plate fixation for the same type of fracture. With a follow-up of more than 12 months, the objective and subjective clinical elbow criteria as well as the overall function of the upper limb and radiological assessment were collected. ResultsWith an average follow up of 24±11 months, 26 patients met the inclusion criteria and received a YALP and 24 patients received double plate. All patients whose fracture had healed except one were pain-free (mean VAS 0.3±0.6). All patients had good subjective results (mean SEV 96%±4). Elbow function was excellent (mean total MEPS 96±4) with normal triceps strength (23/24 patients had a triceps strength graded 5/5 and one patient 4/5) and range of motion (flexion 139±8, extension −7±8 and pronosupination greater than 155 degrees). The operating time was shorter in the YALP group (84 ± 23minutes versus 97 ± 28minutes, p=0.03). The double plate group had more complications; the overall complication rate was significantly higher (p=0.02) in the double 90-degree plate group (12/24, 50%) with four nonunions, four symptomatic ulnar nerves, three hardware removals for pain and one radial nerve injury versus 5/26 complications (19%, p=0.02) in the Y-plate group: one iliac graft for nonunion, 1 plate removal due to functional discomfort, 1 twisted YALP, 1 broke interfragmentary screw and one symptomatic ulnar nerve. DASH, SEV, MEPS scores and flexion-extension range were better in the YALP group. DiscussionYALP produces satisfactory results in supracondylar fractures of the distal humerus. The results of YALP appear to be better than the results with two 90° plates for the same fracture type with a shorter operative time and easier management of fractures with proximal diaphyseal extension. Level of evidenceIII; case control study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Orthopaedics & Traumatology: Surgery & Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.