Abstract

Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracranial pressure. 20% of patients with preeclampsia, the diameter of the optic nerve sheath consistent reaches intracranial pressure values above 20 mmHg.To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia.

Highlights

  • Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological

  • To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia

  • The diameter of the optic nerve sheath was higher with statistical significance (p < 0.05) for both eyes in patients with preeclampsia / eclampsia

Read more

Summary

Introduction

Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracranial pressure. 20% of patients with preeclampsia, the diameter of the optic nerve sheath consistent reaches intracranial pressure values above 20 mmHg.To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia Her measurements using ultrasound transorbital have shown correlation with increased intracranial pressure. 20% of patients with preeclampsia, the diameter of the optic nerve sheath consistent reaches intracranial pressure values above 20 mmHg.To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia

Methods
Results
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call