Abstract

This study describes a fast and efficient method for radiolabeling of etodolac with iodine-125 [125I], where both chloramine-T and iodogen were used as oxidizing agents. The labeling reaction was carried out via electrophilic substitution of hydrogen atom with the iodonium cation I+. The labeling yield was found to be influenced by different factors such as drug concentration, pH of the reaction mixtures, different oxidizing agents, reaction time, temperature and different organic media. The radiochemical yield (RCY) was determined by TLC system using methylene chloride:ethyl acetate (3:7 v/v) as a developing solvent and by electrophoresis using cellulose acetate moistened with 0.02 M phosphate buffer pH 7. The maximum radiochemical yield of [125I]Etodolac (87.7%) was obtained. Labeled etodolac shows a good localization in inflamed muscle. It excretes mainly via kidney and to some via liver.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.