Abstract

A comparison was made between a fixed aerobic biological process and a physicochemical treatment for waste effluents with butyl acetate. An acrylic tank with 100 L capacity and a support medium for PET bottles was implemented for the formation of the biofilm and thus develop the biological reactor. In the experimental phase, concentrations of 10, 20 and 30% of butyl acetate containing sample, using hydraulic retention times of: (16, 8, 5.33 and 4 days) for each concentration. After the experimentation, a removal of 99% of COD and 97% of BOD was obtained. For the physicochemical treatment, coagulant, flocculant, and adjuvants were used, by a jar test. A decrease in 74%, 53.8%, 55%, 97% and 37%, for electrical conductivity, total suspended solids, color, turbidity, COD and BOD respectively, were obtained compared to the initial sample. Both treatments were filtered through a bed packed with activated carbon, sand, and silica gravel. The aim of this work was to evaluate / quantify butyl acetate removal efficiency in each treatment for its subsequent comparison, with prospect to the reduction of similar pollutants in residual effluents is intended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.