Abstract

To compare accuracy of anterior cervical pedicle screws between assist of rapid prototyping 3D guide plate and free-hand insertion, and evaluate the safety of two methods. Eight adult cervical cadaver specimens after formaldehyde immersion, including 4 males and 4 females, aged 32 to 65(40.3±5.6) years old. After X-ray examination to exclude bone damage and deformity, 4 of them (3D guide plate group) randomly selected were for CT scan to obtain DICOM format data, and the data was imported into Mimics software for model, designed the ideal entry point and nail path for anterior cervicaltranspedicular screw (ATPS). After obtaining the personalized guide plate of the nail channel, it was exported as STL data, and the individual guide plate was printed by rapid prototyping and 3D printing technology. In turn, with the assistance of 3D guide plates, one-to-one personalized ATPS screws were placed on the four lower cervical cadaver specimens. Another 4 (free-hand group) lower cervical cadaver specimens were implanted with ATPS screws using free-hand technique. All specimens were performed CT thin-layer scanning and three-dimensional reconstruction after operation. The Tomasino method was used to evaluate the safety of the screws on the CT cross-sectional and sagittal images, to determine whether there was a cortical puncture of the lower and inner edges of the pedicle. According to the CT rating results, gradeⅠandⅡwere safe, and grade Ⅲ- Ⅴ were dangerous.And the accuracy of screws was recorded and analyzed between two groups. Two screws were inserted in each segment from C3 to C7 in 8 adult cadavers. A total of 80 screws were inserted, 40 in the 3D guide plate group, and 40 in the free-hand group. The Tomasino screw rating method was used to evaluate the safety of screw, 21 screws were gradeⅠ, 14 screws were gradeⅡ, 3 screws were grade Ⅲ, 1 screw was grade Ⅳ, 2 screws were grade Ⅴ in 3D guide plate group, while 14 screws were gradeⅠ, 8 screws were gradeⅡ, 8 screws were grade Ⅲ, 6 screws were grade Ⅳ, 2 screws were grade Ⅴ in free-hand group. The safety rate of 3D guide plate group was 87.5%, and 55.0% of the free hand group (χ2=8.7, P=0.003). The 3D printing rapid prototyping guide plate assisted insertion of the anterior cervical pedicle screw can significantly improve the accuracy and safety, and provide a theoretical basis for further clinical application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.