Abstract

We report on the results of the computer simulation of the operation of magnetodynamic break switches used as the second stage of current pulse formation in magnetic explosion generators. The simulation was carried out under the conditions when the magnetic field energy density on the surface of the switching conductor as a function of the current through it was close to but still did not exceed the critical value typical of the beginning of electric explosion. In the computational model, we used the parameters of experimentally tested sample of a coil magnetic explosion generator that can store energy of up to 2.7 MJ in the inductive storage circuit and equipped with a primary explosion stage of the current pulse formation. It has been shown that the choice of the switching conductor material, as well as its elastoplastic properties, considerably affects the breaker speed. Comparative results of computer simulation for copper and aluminum have been considered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.