Abstract

In a developing country like India the benefits of Post-Tensioning system are yet to be recognized. The post-tensioning method is now a day’s being adopted widely due to its applications. By using post-tensioning method one can achieve the most economical and safe design for commercial as well as residential buildings. The present study focuses on Post-Tensioned flat slab systems with respect to strength, service and cost estimation. The designs were analysed using ADAPT Builder software with different panel sizes. The results indicate that PT slabs have better moment carrying capacity & Deflection; also the costs are better than the RC flat slab systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call