Abstract

This paper reports some results of an experimental investigation on performance of four different types of collectors. These include the flat plate collector and the parabolic cylindrical, compound parabolic and conical concentrators. The flat plate collector with two glass covers was found to be best suited for use in Delhi, provided the required maximum temperature did not exceed 95° C. Among the concentrating collectors tested, the conical collector with conical absorber, gave significantly higher temperatures for the same concentration ratio. The conical reflector is also easier to fabricate as compared to parabolic reflectors. The requirement of high reflectivity and its continued maintenance for a concentrator, is a major drawback of a concentrating collector.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.