Abstract

Background: Comparative outcome studies investigating internal Double-J (DJ) and externalized stents have primarily been performed for open and laparoscopic pyeloplasty, with a paucity of literature surrounding outcomes in robot-assisted laparoscopic pyeloplasty (RALP). Furthermore, outcomes of a modified external stent inserted into the renal pelvis, termed cutaneous pyeloureteral (CPU) stent, remain unexamined. This study investigates outcomes of DJ and CPU stents as methods of trans-anastomotic drainage. Materials and Methods: A retrospective analysis identified pediatric patients who underwent RALP between December 2007 and January 2020 at a single tertiary center, where CPU stents were introduced in June 2012. Operative success was defined as improved or stable hydronephrosis without subsequent redo pyeloplasty. Secondary outcomes included stent reinsertion, anesthesia requirements, opioid administration, urinary tract infection (UTI), and bladder spasms. Results: A total of 103 pediatric RALP procedures were analyzed (DJ = 70, CPU = 33). Operative success (DJ = 95.7%, CPU = 100%, p = 0.55), Society for Fetal Urology (SFU) grade improvement, and length of stay were comparable. Accidental stent expulsion was only seen with CPU stents (9%; p = 0.03). Intracorporeal stent migration also occurred more frequently in CPU stents (DJ = 3%, CPU = 15%, p = 0.03). Stent reinsertion, when needed, used a DJ stent with rates of 4% and 9% for DJ and CPU stents, respectively (p = 0.38). DJ stents were removed at a later postoperative day (DJ = 45.2 ± 25.0, CPU = 8.3 ± 4.2; p < 0.001) with increased general anesthesia (DJ = 99%, CPU = 3%; p < 0.001) and intravenous (IV) opioid (DJ = 27%, CPU = 9%; p = 0.04) requirements. Finally, DJ stents had nonsignificant increased rates of UTI (DJ = 17%, CPU = 3%, p = 0.06) and bladder spasms necessitating postoperative medication (DJ = 26%, CPU = 9%, p = 0.07). Conclusions: DJ and CPU stents display equivalent success rates in pediatric RALP and similar stent reinsertion rates. Appreciable differences can inform stent selection, including higher general anesthesia requirements and IV opioid administration among DJ stents and a higher incidence of accidental stent expulsion among CPU stents. In addition, DJ stents were associated with nonsignificant increased rates of UTI and bladder spasm necessitating medication.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call