Abstract

Plasma position on CASTOR tokamak is measured by several systems based on different experimental methods. Vertical and horizontal plasma displacements are deduced from data of 4 Mirnov coils spaced poloidaly by 45°. Output of the Mirnov coils is routinely used as an input for automatic feed-back control of plasma position on CASTOR. Independently, we used an array of 16 Hall sensors, which measure the required magnetic field directly. Additional information on plasma position is obtained from two arrays of bolometers that measure horizontal and vertical profile of plasma radiation. Principle design of the all used diagnostics is given. Comparison of horizontal and vertical displacements deduced using various experimental methods is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.